DrivE-Tech MINI
DrivE-Tech MINI
DRIVE-TECH MINI
The DrivE-Tech MINI is an easy-to-use, versatile and highly featured variable frequency drive. It can be used in a wide range of pumping applications, from the residential household constant pressure control to light commercial multi-pump pressure boosting. Combined with specifically designed features, mobile app with remote control and a robust IP66, outdoor-rated, enclosure the Drive-Tech MINI improves, controls and protects surface or submersible pumping systems.
-
CONFIGURATION
- Compatible with three-phase induction or permanent magnet motors
- Available in 1~230V IN / 3~230V OUT or 3~400V IN / 3~400V OUT
- Easy setup with multi level user access and presets
- Programmable Input/Output terminal options
- Outdoor rated IP66 enclosure for use in harsh environments
- Direct wall mount and surface pump mounting
- Low harmonic drive design to meet EN61000-3-12
- Integrated Input filter for use in first environment C1 EN61800-3
APPLICATION-SPECIFIC FEATURES
- Pump specific features, including: constant water pressure, flow, level control
- Multi pump operation controlling a second pump at constant speed
- Combo operation connecting up to 8 Drive-Tech MINI units
- Alternating pump mode
- Surface or submersible pump cascading
- Constant speed mode with 2 setpoints
OPERATION
- Integrated multi row OLED display showing alarms, pump speed, set point and more
- Fully controllable through Unyconnect mobile app
- Real-time fault logging with date and time stamps
- MPPT control for PV-panel powered solar pumping applications
- Multi power operation allows to use AC and DC supply voltage
PROTECTION
- Protection against short circuit, surges, underload, overload, drive overheat, undervoltage, overvoltage, phase loss, phase imbalance, overpressure, sensor fault, etc.
- Pump dry run
- Locked rotor or pump
COMMUNICATION
- RS-485 Communications (Modbus) multi pump operation, remote control and monitoring
- Bluetooth connectivity with Unyconnect mobile app
- Bridge mode using 2 smartphones and GSM/Wifi connection for permanent remote control
- Communications for multi-drive operations up to 8 VFDs
DrivE-Tech MINI / DrivE-Tech COMPACT Specification
Mains Connection Input voltage 1ph 220-240 V; 3ph 380-460 V Input frequency 50-60 Hz (+/- 2%) Displacement power factor (cosphi) near unity > 0.98 Motor controls Control methods V/F and SVC (Sensorless Vector Control) Control type PWM (pulse width modulation) Frequency Setting Resolution Digital Reference: 0.01 Hz Frequency Accuracy Digital: 0.01 % of Max. Output Frequency V/F Control Curve Adjustable V/F curve Maximum Output Frequency 1ph 220-240 V models: 300 Hz; 3ph 380- 460VAC models: 300 Hz Overload Capacity 110% of VFD rated current for 1 minute during every 5 minutes of operation Protection Operation Method Keypad / Terminals / RS-485 Modbus Communication / Bluetooth Mobile App control Analog Input 4 Analog Inputs (2x 0- 10VDC) (2x 4- 20mA) By Digital Inputs Start Signal Forward, Reverse Stop Signal Motor ramp down Digital Input 4 programmable digital inputs (Normally Open / Normally Closed), motor run, motor stop Fault Reset Resets VFD faults via keypad, digital input or communication. Some critical faults can only be reset by cycling the VFD power. Outputs 2x Multi-Function Outputs 2 programmable digital outputs (NO, NC), motor run signal, alarm signal RS 485 Serial Port Output Frequency, Output Current, Output Voltage, Output kW, DC Link Voltage General Operation Functions Frequency Limit, Jump Frequencies, 2nd ACC/DEC, Auto Restart, Auto-Tuning, PID w/sleep, Temperature Foldback, Run Delay, Minimum Run Timer, PM Motor Control and Auto-Tuning Pump Operation Functions/Protections Sleep Mode, Pipe Fill, PID, Overpressure, Dry Run (Underload), HLD (High Load), Broken Pipe, No-Flow Protection VFD Fault Trips Over Voltage, Low Voltage, Over Current, Overload, Short Circuit, Ground Fault, VFD Overheat, Input Phase Loss, Signal Loss, Hardware Fault, etc. Motor Overload Adjustable electronic motor overload protection Motor temperature 3-wire PT100 motor temperature protection (on request) Overcurrent 220-240 VAC variable torque: at 110% of VFD rated current 380-460 VAC variable torque: at 110% of VFD rated current Overvoltage 380-460 VAC models: at 820VDC DC bus voltage Overtemperature Built-in IGBT and capacitor bank temperature sensors VFD Alarm Stall Prevention at ACC and DEC, Overload, Thermal Sensor Fault, Capacitors High Temperature, Signal Loss, Overpressure, Underload, High Load, etc. Keypad Display Operation Information Output Frequency, Output Current, Output Voltage, Frequency Reference, Operating Speed, DC Voltage, kWattmeter, Run-time, Last Trip Time, Pressure, etc. Fault Provides 6 fault records and logs 30 faults Environ- ment Operating Temperature -10 °C ~ 40 °C (14 °F ~ 104 °F) Storage temperature -10 °C ~ 60 °C (14 °F ~ 140 °F) Ambient Humidity up to 95 % RH. (non-condensing) Altitude Normal up to (1000 m), -1% derating every 100 m Vibration and Impact Complies with EN 60068-2-6:2008 and EN60068-2-27:2009 and EN60068-2-64:2008 Enclosure Ratings IP66 Max. Input efficiency (>=X%) Drive model DrivE-Tech MINI DrivE-Tech COMPACT Input voltage 220-240 AC 95 95 380-460 VAC 96 97 CE Low Voltage EN6100-5-1 CE EMC EN61800-3, EN61000-3-12, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8, IEC61000-6-2, IEC61000-6-4 Other C-Tick, ROHS -
MODEL NUMBER DRIVE-TECH MINI
Drive model no. drive type IP V IN [V] I OUT [A] dimensions [mm] weight [kg] 2149005 DT MINI 2.005 M/T 66 1x220-240 3 150 x 211 x 130 2.5 2149112 DT MINI 2.011 M/T 66 1x220-240 5 150 x 211 x 130 2.5 2149152 DT MINI 2.015 M/T 66 1x220-240 7.5 150 x 211 x 130 2.5 314000170 DT MINI 2.022 M/T 66 1x220-240 8.5 150 x 211 x 130 2.5 314000162 DT MINI 4.011 T/T 66 3x380-460 4 150 x 211 x 130 2.5 314000163 DT MINI 4.022 T/T 66 3x380-460 6 150 x 211 x 130 2.5 314000164 DT MINI 4.040 T/T 66 3x380-460 10.5 150 x 211 x 130 2.5 -