FDP Series
FDP Series
Submersibile pumps for professional drainage
40-50 FDP: Submersible electric pumps in cast iron and stainless steel, suitable for draining clear and turbid waters. They can be used as ready-to-use portable pumps both for construction site use, basement wells, and for fixed installations with control panel.
70-80-100-150 FDP: Submersible electric pumps suitable for draining clear and turbid water. Suitable for use on construction sites and for pumping liquids, including abrasive ones. Due to their handling they can be easily transported.
-
Applications
- Drainage and dewatering
- Rainwater Recovery
- Construction site drainage and dewatering
- Mining, Quarrying drainage and dewatering
- Emergency flood water drainage
Related Products
40-50FDP 50 Hz
Materials/Constr.design Open impeller Cast iron EN GJL200 External casing Aluminium alloy EN AW6060 Pump body Aluminium alloy Cover Aluminium alloy Filter Aluminium alloy Wear plate 40FDP-52-1,0M Stainless steel AISI304 50FDP-52-1,4M, 50FDP-52-1,8M Aluminium alloy with rubber coating Mechanical seal Silicon carbide (SiC/SiC) Motor shaft Stainless steel AISI420 Power cable Type 10 m H07RN-F type Single-phase 40FDP-52-1,0M 4G1,5mm², capacitor box and SCHUKO plug (CEE 7/VII) Single-phase 50FDP-52-1,4M, 50FDP-52-1,8M 4G2,5mm², capacitor box and SCHUKO plug (CEE 7/VII) Three-phase 4G1,5mm² Motor Constr.design asynchronous squirrel cage-type oil filled Type 2 poles; 50 Hz Insulation class F Protection degree IP68 Voltage Single-phase 230V ±6% built-in overheating protection (up to 1,1 kW), float switch as optional Three-phase 230V ±10%, 400V ±10% Limits of use Maximum liquid temperature + 40°C pH of pumped liquid 5 - 8 Liquid density 1,0 Kg/dm³ Maximum immersion depth: 5 m Min. immersion depth for continuos service see “Dimensional drawings” Free passage 6 mm Max. number of starting/hour 20 Construction options:
- 60 Hz version
- Different voltages
- Food-grade white oil40FDP-HH 50 Hz
Materials/Constr.design Double open impeller Cast iron EN GJL200 External casing Aluminium alloy EN AW6060 Pump body Aluminium alloy Cover Aluminium alloy Filter Aluminium alloy Wear plate Stainless steel AISI304 Mechanical seal Silicon carbide (SiC/SiC) Motor shaft Stainless steel AISI431 Power cable Type 10 m H07RN-F type Single-phase 4G2,5mm², capacitor box and SCHUKO plug (CEE 7/VII) Three-phase 4G1,5mm² Motor Constr.design asynchronous squirrel cage-type oil filled Type 2 poles; 50 Hz Insulation class F Protection degree IP68 Voltage Single-phase 230V ±6%, float switch as optional Three-phase 230V ±10%, 400V ±10% Limits of use Maximum liquid temperature + 40°C pH of pumped liquid 5 - 8 Liquid density 1,0 Kg/dm³ Maximum immersion depth: 5 m Min. immersion depth for continuos service 331 mm Free passage 6 mm Max. number of starting/hour 20 Construction options:
- 60 Hz version
- Different voltages
- Food-grade white oil70/80FDP 50 Hz
Materials/Constr.design Open impeller Martensitic stainless steel External casing Aluminium alloy Pump body Aluminium alloy Cover Aluminium alloy Filter Stainless steel AISI304 Wear plate Graphite/Alumina Mechanical seal Silicon carbide (SiC/SiC) Motor shaft Stainless steel AISI420 Power cable Type 10 m H07RN-F type Single-phase 70FDP-52-2,2M 4G2,5mm², capacitor box and SCHUKO plug (CEE 7/VII) Three-phase 80FDP-52-4,1T 4G2,5mm² Three-phase 4G1,5mm² Motor Constr.design asynchronous squirrel cage-type in dry chamber Type 2 poles; 50 Hz Insulation class F Protection degree IP68 Voltage Single-phase 230 V ±6% Three-phase 230V ±10%, 400V ±10% Limits of use Maximum liquid temperature + 40°C pH of pumped liquid 5 - 8 Liquid density 1,1 Kg/dm³ Maximum immersion depth: 5 m Min. immersion depth for continuos service 457 mm Free passage 6 mm Max. number of starting/hour 20 Construction options:
- 60 Hz version
- Different voltages
- With coating in composite material for wear protection (possible variations of the hydraulic performance)100FDP 50 Hz
Materials/Constr.design Open impeller High chrome cast iron External casing Stainless steel AISI304 Pump body Cast iron EN GJL 200 with rubber coating Cover Cast iron EN GJL250 Filter Stainless steel AISI304 Wear plate Cast iron EN GJL 250 with rubber coating Mechanical seal motor side Graphite/Alumina pump side Silicon carbide (SiC/SiC) Motor shaft Stainless steel AISI431 Power cable Type 20 m S1RN8-F type Three-phase 100FDP-52-5,5T, 100FDP-52-6,5T 4G2,5+3x1mm² Three-phase 100FDP-52-8,1T 4G4+3x1mm² Motor Constr.design asynchronous squirrel cage-type in dry chamber Type 2 poles; 50 Hz Insulation class F Protection degree IP68 Voltage Three-phase 400V ±10% Limits of use Maximum liquid temperature + 40°C pH of pumped liquid 6 - 10 Liquid density 1,1 Kg/dm³ Maximum immersion depth: 15 m Min. immersion depth for continuos service 150 mm Free passage 10 mm Max. number of starting/hour 15 Construction options:
- 60 Hz version
- Different voltages
- Inner control of the thermal probes in the winding, control sequence and lack of phase (on request)100/150 FDP-LH/HH 50 Hz
Materials/Constr.design Open impeller High chrome cast iron External casing Stainless steel AISI304 Pump body Cast iron EN GJL 200 with rubber coating Cover Cast iron EN GJL250 Filter Stainless steel AISI304 Wear plate Cast iron EN GJL 250 with rubber coating Mechanical seal motor side Graphite/Alumina pump side Silicon carbide (SiC/SiC) Motor shaft Stainless steel AISI431 Power cable 20 m 7G4+2x1,5mm², 07RN-F type Motor Constr.design asynchronous squirrel cage-type in dry chamber Type 2 poles; 50 Hz Insulation class F Protection degree IP68 Voltage Three-phase 400V ±10% Limits of use Maximum liquid temperature + 40°C pH of pumped liquid 6 - 10 Liquid density 1,1 Kg/dm³ Maximum immersion depth: 15 m Min. immersion depth for continuos service 200 mm Free passage 6 mm Max. number of starting/hour 10 Construction options:
- 60 Hz version
- Different voltages
- Inner control of the thermal probes in the winding, control sequence and lack of phase (on request)150FDP 50 Hz
Materials/Constr.design Open impeller Stainless steel AISI304 External casing Aluminium alloy Pump body Aluminium alloy with rubber coating Cover Aluminium alloy Filter Aluminium alloy Wear plate Stainless steel AISI304 with rubber coating Mechanical seal motor side Graphite/Alumina pump side Silicon carbide (SiC/SiC) Motor shaft Stainless steel AISI431 Power cable 20 m 7G4+2x1,5mm², 07RN-F type Motor Constr.design asynchronous squirrel cage-type in dry chamber Type 2 poles; 50 Hz Insulation class F Protection degree IP68 Voltage Three-phase 400V ±10% Limits of use Maximum liquid temperature + 40°C pH of pumped liquid 5 - 8 Liquid density 1,1 Kg/dm³ Maximum immersion depth: 15 m Min. immersion depth for continuos service 350 mm Free passage 7 mm Max. number of starting/hour 10 Construction options:
- 60 Hz version
- Different voltages -
40-50 FDP 50 Hz
Pump model Phase Q = Delivery l/sec 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2 28,8 32,4 36 39,6 43,2 46,8 50,4 54 US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9 126,8 142,6 158,5 174,3 190,2 206 221,9 237,7 H = Total meters head of water column [m] 40FDP-52-1,0 1 ~ 18 16,5 15 13,5 11 8 4,5 1 3 ~ 18 16,5 15 13,5 11 8 4,5 1 40FDP-52-1,1 3 ~ 20 18,5 17 15,5 13,5 11 8,5 5 50FDP-52-1,4 1 ~ 14,3 14,1 13,7 13,1 12,5 11,8 11 9,8 8,5 7 6 4,5 2,8 50FDP-52-1,8 1 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2 3 ~ 16,6 16,3 16,1 15,8 15,1 14,2 14 12,8 11,8 10,2 9 7 5,8 4 2 50FDP-52-2,2 3 ~ 18,5 18,5 18,2 17,8 17,5 16,5 16 14,7 13,9 12 10,5 9,1 7,5 5,8 4 2 40 FDP HH 50 Hz
Pump model Phase Q = Delivery l/sec 0 1 2 3 4 5 6 7 m³/h 0 3,6 7,2 10,8 14,4 18 21,6 25,2 US gpm 0 15,8 31,7 47,5 63,4 79,2 92,1 110,9 H = Total meters head of water column [m] 40FDP-52-1,4 HH 1 ~ 31 27 23 19 14,5 10 5,2 40FDP-52-1,8 HH 1 ~ 32 29,5 26 22 18 13 7,8 2 3 ~ 32 29,5 26 22 18 13 7,8 2 70-80 FDP 50 Hz
Pump model Phase Q = Delivery l/sec 0 2 4 6 8 10 12 15 20 25 28 m³/h 0 7,2 14,4 21,6 28,8 36 43,2 54 72 90 100,8 US gpm 0 31,7 63,4 92,1 126,8 158,5 190,2 237,7 317 396,2 443,8 H = Total meters head of water column [m] 70FDP-52-2,2 1 ~ 16 15 14 12,8 11,3 9,6 8 5 3 ~ 16 15 14 12,8 11,3 9,6 8 5 70FDP-52-3,5 3 ~ 21 20,5 19,5 18,5 17 15,5 13,5 9,5 4 80FDP-52-4,1 3 ~ 23,3 22,9 22,5 21 20,5 18,5 17,5 15,8 11,5 6,5 3,8 100 FDP 50 Hz
Pump model Phase Q = Delivery l/sec 0 2,5 5 10 15 20 25 30 35 40 45 50 m³/h 0 9 18 36 54 72 90 100,8 108 144 162 180 US gpm 0 39,6 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5 H = Total meters head of water column [m] 100FDP-52-5,5 LH 3 ~ 18,9 17,5 15,7 13,4 11,3 9,1 7 5,1 2,5 100FDP-52-5,5 HH 3 ~ 30 27,9 26 20,8 14,6 6,3 100FDP-52-6,5 LH 3 ~ 22,4 21,4 20 17,6 15,1 12,7 10,9 8,8 6,6 3 100FDP-52-6,5 HH 3 ~ 35,3 32,3 29,5 23,2 16,7 8,3 100FDP-52-8,1 LH 3 ~ 25,9 24,6 22,9 20,7 18,3 15,9 14,1 12,1 9,7 6,8 3 100FDP-52-8,1 HH 3 ~ 45 40,7 36,6 28,8 20,2 10,1 100/150 FDP-LH/HH 50 Hz
Pump model Phase Q = Delivery l/sec 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 m³/h 0 18 36 54 72 90 100,8 108 144 162 180 198 216 234 252 US gpm 0 79,2 158,5 237,7 317 396,2 443,8 475,5 634 713,3 792,5 871,8 951 1030,3 1109,5 H = Total meters head of water column [m] 150FDP-52-11 LH 3 ~ 30 28,3 26,8 24,8 22,8 21 19,3 17,2 15,3 13 10,7 6,7 3 100FDP-52-11 HH 3 ~ 60 52,8 44,9 35,3 24 10 150FDP-52-15 LH 3 ~ 32 30,6 29,3 27,8 26,4 24,3 22,3 20,3 18,5 16,6 14,8 12,4 10,1 6 2 100FDP-52-15 HH 3 ~ 62 54,6 48,4 42 35,1 25,8 16,4 2,3 150FDP 50 Hz
Pump model Phase Q = Delivery l/sec 0 20 25 30 35 40 45 50 60 70 80 90 m³/h 0 72 90 100,8 108 144 162 180 216 252 288 324 US gpm 0 317 396,2 443,8 475,5 634 713,3 792,5 951 1109,5 1268 1426,5 H = Total meters head of water column [m] 150FDP-52-22 3 ~ 35 32 31 29 28 26 24 22 18,5 15 11 5 -
Brochures
Manuals