  • Encapsulated Standard Motors

    The new PT100 temperature sensor for 6" and 8" Encapsulated standard motors is equipped with a 4-wire shielded supply cable, available in various lengths, adding additional protection against high frequency disturbances which can occur in applications with variable frequency drives.

    The enclosed adaptor screw only needed for installation in 6" and 8" encapsulated standard and permanent magnet motors is now separated from the PT100 sensor allowing for an easy, quick and secure installation.

    To install the PT100 sensor bolt, remove the top end bell bolt that is opposite of the lead and replace it with the PT100 screw. Tighten the sensor bolt to the torque values shown below.

    • 6" PT100
    • 4 kW-45 kW: 54- 61 Nm
    • *Tightening torque PT 100 Inbus-screw M4 : 3 - 4 Nm
    • 8" PT100
    • 30 kW-45 kW: 54- 61 Nm
    • 55 kW-150 kW: 115- 122 Nm

    The PT100 is not a motor overload protector, which means the warranty will be voided if a separate motor protector is not installed as required by the Franklin Electric Application Inastallation Maintenance Manual (AIM).

    Encapsulated Motors HighTemp

    It's ohmic resistance is proportional to the sensed temperature. The FE field replaceable PT100 is potted into a screw holding the upper end bell. Because of his remote position relative to the windings, the sensing relay should be adjusted according to the below table. The above-ground equipment is not available from Franklin Electric and is typically part of a custom panel or data acquisition system,it is available from specialty dealers. .

    To install the PT100 sensor bolt, remove the top end bell bolt that is opposite of the lead and replace it with the PT100 screw. Tighten the sensor bolt to the torque values shown below.

    • 6" PT100 HighTemp
    • 4 kW-30 kW: 54- 61 Nm
    • 8" PT100 HighTemp
    • 30 kW-110 kW: 115 - 122 Nm

    The PT100 is not a motor overload protector, which means the warranty will be voided if a separate motor protector is not installed as required by the Franklin Electric Application Inastallation Maintenance Manual (AIM).

  • Encapsulated Motors Temperature Conditions

    ConditionsTemp. of the Water
    Without Motor Operation
    Max. Trip Temp. / Resistance Setting
    (for standard lead length)
    Motor operating at nameplate output
    with 0.16 m/sec flow past the motor
    10 °C40 °C / 115.5 Ω
    15 °C44 °C / 117.0 Ω
    20 °C48 °C / 118.6 Ω
    25 °C51 °C / 119.7 Ω
    30 °C55 °C / 121.3 Ω
    Motor that has been derated
    with 1 m/sec flow past the motor
    35 °C59 °C / 122.8 Ω
    40 °C63 °C / 124.3 Ω
    45 °C66 °C / 125.5 Ω
    50 °C70 °C / 127.0 Ω
    55 °C74 °C / 128.6 Ω
    60 °C78 °C / 130.1 Ω

    6" PT100 Standard Encapsulated Motors Model Numbers

    Kit NumberLead length
    [m]
    Motor TypeWire Insul.Screw Materialmax. Medium Temp.
    [°C]
    Lead Ø
    [mm²]
    D
    [mm]
    305 327 951106" all Ratings
    Rubber,
    shielded
    316SS603X0,58.5
    305 327 95220
    305 327 95330
    305 327 95450

    8" PT100 Standard Encapsulated Motors Model Numbers

    Kit NumberLead length
    [m]
    Motor TypeWire Insul.Screw Materialmax. Medium Temp.Lead Ø
    [mm²]
    D
    [mm]
    305 326 95110Motors Type 1
    and Type 2.1

    Rubber,
    shielded
    316SS60°C3X0,58.5
    305 326 95220
    305 326 95330
    305 326 95450

    Encapsulated Motors HiTemp Temperature Conditions

    ConditionsTemp. of the Water
    Without Motor Operation
    Max. Trip Temp. / Resistance Setting
    Motor operating at nameplate output
    with 0.16 m/sec flow past the motor
    50 °C60 °C
    60 °C70 °C
    70 °C80 °C
    75 °C85 °C
    80 °C90 °C
    90 °C100 °C

    6" Encapsulated Motors HiTemp90 Model Numbers

    Kit NumberMotor TypeWire Insul.Screw Materialmax. Medium Temp.Lead [mm²]Lead length [m]
    156 098 111K4 - 30kWSilicon1.457190°C4X0,3510
    156 098 112KSilicon1.457190°C4X0,35130

    8" Encapsulated Motors HiTemp75 Model Numbers

    Kit NumberMotor TypeWire Insul.Screw Materialmax. Medium Temp.Lead [mm²]Lead length [m]
    156 098 116K30 - 110kW (Type 1)Silicon1.457190°C4X0,3510
    156 098 117KSilicon1.457190°C4X0,35130