Encapsulated Standard Motors
The new PT100 temperature sensor for 6" and 8" Encapsulated standard motors is equipped with a 4-wire shielded supply cable, available in various lengths, adding additional protection against high frequency disturbances which can occur in applications with variable frequency drives.
The enclosed adaptor screw only needed for installation in 6" and 8" encapsulated standard and permanent magnet motors is now separated from the PT100 sensor allowing for an easy, quick and secure installation.
To install the PT100 sensor bolt, remove the top end bell bolt that is opposite of the lead and replace it with the PT100 screw. Tighten the sensor bolt to the torque values shown below.
- 6" PT100
- 4 kW-45 kW: 54- 61 Nm
- *Tightening torque PT 100 Inbus-screw M4 : 3 - 4 Nm
- 8" PT100
- 30 kW-45 kW: 54- 61 Nm
- 55 kW-150 kW: 115- 122 Nm
The PT100 is not a motor overload protector, which means the warranty will be voided if a separate motor protector is not installed as required by the Franklin Electric Application Inastallation Maintenance Manual (AIM).
Encapsulated Motors HighTemp
It's ohmic resistance is proportional to the sensed temperature. The FE field replaceable PT100 is potted into a screw holding the upper end bell. Because of his remote position relative to the windings, the sensing relay should be adjusted according to the below table. The above-ground equipment is not available from Franklin Electric and is typically part of a custom panel or data acquisition system,it is available from specialty dealers. .
To install the PT100 sensor bolt, remove the top end bell bolt that is opposite of the lead and replace it with the PT100 screw. Tighten the sensor bolt to the torque values shown below.
- 6" PT100 HighTemp
- 4 kW-30 kW: 54- 61 Nm
- 8" PT100 HighTemp
- 30 kW-110 kW: 115 - 122 Nm
The PT100 is not a motor overload protector, which means the warranty will be voided if a separate motor protector is not installed as required by the Franklin Electric Application Inastallation Maintenance Manual (AIM).
Related Products
-
Encapsulated Motors Temperature Conditions
Conditions Temp. of the Water
Without Motor OperationMax. Trip Temp. / Resistance Setting
(for standard lead length)Motor operating at nameplate output
with 0.16 m/sec flow past the motor10 °C 40 °C / 115.5 Ω 15 °C 44 °C / 117.0 Ω 20 °C 48 °C / 118.6 Ω 25 °C 51 °C / 119.7 Ω 30 °C 55 °C / 121.3 Ω Motor that has been derated
with 1 m/sec flow past the motor35 °C 59 °C / 122.8 Ω 40 °C 63 °C / 124.3 Ω 45 °C 66 °C / 125.5 Ω 50 °C 70 °C / 127.0 Ω 55 °C 74 °C / 128.6 Ω 60 °C 78 °C / 130.1 Ω 6" PT100 Standard Encapsulated Motors Model Numbers
Kit Number Lead length
[m]Motor Type Wire Insul. Screw Material max. Medium Temp.
[°C]Lead Ø
[mm²]D
[mm]305 327 951 10 6" all Ratings
Rubber,
shielded316SS 60 3X0,5 8.5 305 327 952 20 305 327 953 30 305 327 954 50 8" PT100 Standard Encapsulated Motors Model Numbers
Kit Number Lead length
[m]Motor Type Wire Insul. Screw Material max. Medium Temp. Lead Ø
[mm²]D
[mm]305 326 951 10 Motors Type 1
and Type 2.1
Rubber,
shielded316SS 60°C 3X0,5 8.5 305 326 952 20 305 326 953 30 305 326 954 50 Encapsulated Motors HiTemp Temperature Conditions
Conditions Temp. of the Water
Without Motor OperationMax. Trip Temp. / Resistance Setting Motor operating at nameplate output
with 0.16 m/sec flow past the motor50 °C 60 °C 60 °C 70 °C 70 °C 80 °C 75 °C 85 °C 80 °C 90 °C 90 °C 100 °C 6" Encapsulated Motors HiTemp90 Model Numbers
Kit Number Motor Type Wire Insul. Screw Material max. Medium Temp. Lead [mm²] Lead length [m] 156 098 111K 4 - 30kW Silicon 1.4571 90°C 4X0,35 10 156 098 112K Silicon 1.4571 90°C 4X0,35 130 8" Encapsulated Motors HiTemp75 Model Numbers
Kit Number Motor Type Wire Insul. Screw Material max. Medium Temp. Lead [mm²] Lead length [m] 156 098 116K 30 - 110kW (Type 1) Silicon 1.4571 90°C 4X0,35 10 156 098 117K Silicon 1.4571 90°C 4X0,35 130 -