MHp Horizontal Multistage Self-priming Pumps
MHp Horizontal Multistage Self-priming Pumps
Reliable self-priming performance for pressure boosting and demanding applications
The MHp Series comprises horizontal multistage pumps with self-priming functionality, designed for consistent operation in pressure boosting systems, HVAC installations, fertigation processes, cooling circuits, and a wide range of building services and industrial uses. An advanced intermediate priming stage effectively evacuates trapped air from the hydraulic circuit, ensuring fast priming and reduced downtime in any operating condition.
Built with a reinforced stainless steel outer casing and a high-protection mechanical seal in silicon carbide, the MHp range offers exceptional durability and long service life, even in harsh environments. With flow rates of up to 7 m³/h, heads reaching up to 82 m, and working pressures up to 10 bar, these pumps guarantee efficient and stable operation. Available in single-phase and three-phase versions, MHp pumps combine performance, reliability, and installation flexibility.
-
Applications
- Pressure boosting in residential buildings
- Heating and conditioning
- Fertigation
- General industry
Features
- Mechanical seal SIC/SIC/EPDM
- Outstanding strength and durability, engineered even for the most demanding conditions
- Priming capacity in any situation
- Smart design due to the self-priming intermediate stage which moves air bubbles outside
- Suitable for industrial application
- HVAC, fertigation, cooling systems, pressure boosting
- High protection of mechanical seal
- Seal housing disc with deflector which protects mechanical seal from air bubbles
- Reduced risk of downtime
- Thanks to the new priming system
Related Products
-
Single-phase 3MHp
PUMP MODEL Q = Delivery l/min 0 16,6 25 28,3 41,7 50 66,7 100 m³/h 0 1 1,5 1,7 2,5 3 4 6 US gpm 0 4,4 6,6 7,5 11 13,2 17,6 26,4 H = Total meters head of water column [m] 3MHp04-I-M52005-QQE 43,5 38,4 37,4 32,5 29 21,4 3MHp05-I-M52007-QQE 54,1 47,3 46,1 39,9 35,6 26,1 3MHp06-I-M52011-QQE 65,5 57,7 56,1 48,9 43,7 32,4 3MHp07-I-M52011-QQE 76 66,5 64,7 56,2 50,1 37 Three-phase 3MHp
PUMP MODEL Q = Delivery l/min 0 16,6 25 28,3 41,7 50 66,7 100 m³/h 0 1 1,5 1,7 2,5 3 4 6 US gpm 0 4,4 6,6 7,5 11 13,2 17,6 26,4 H = Total meters head of water column [m] 3MHp04-I-T5B007-QQE 43,3 37,8 36,8 31,8 28,3 20,7 3MHp05-I-T5B007-QQE 53,6 46,3 45 38,7 34,4 24,9 3MHp06-I-T5B011-QQE 65,9 58,3 56,8 49,6 44,5 33,2 3MHp07-I-T5B011-QQE 76,5 67,4 65,7 57,2 51,2 38,1 Single-phase 5MHp
PUMP MODEL Q = Delivery l/min 0 28,3 33,3 41,7 50 66,7 100 116,7 133,3 m³/h 0 1,7 2 2,5 3 4 6 7 8 US gpm 0 7,5 8,8 11 13,2 17,6 26,4 30,8 35,2 H = Total meters head of water column [m] 5MHp04-I-M52011-QQE 46,6 43,1 41,9 40,7 38 29,6 23,2 5MHp05-I-M52011-QQE 57,9 53,2 51,7 50,1 46,5 35,8 27,8 5MHp06-I-M52015-QQE 70,3 65,2 63,4 61,7 57,6 45,2 35,7 5MHp07-I-M52015-QQE 81,7 75,5 73,4 71,4 66,5 51,9 40,7 Three-phase 5MHp
PUMP MODEL Q = Delivery l/min 0 28,3 33,3 41,7 50 66,7 100 116,7 133,3 m³/h 0 1,7 2 2,5 3 4 6 7 8 US gpm 0 7,5 8,8 11 13,2 17,6 26,4 30,8 35,2 H = Total meters head of water column [m] 5MHp04-I-T5B011-QQE 46,4 42,9 41,6 40,4 37,3 27,9 20,9 5MHp05-I-T5B011-QQE 57,8 53,2 51,6 50 46,2 34,6 25,8 5MHp06-I-T5B015-QQE 69,1 63,4 61,4 59,5 54,9 41,1 30,7 5MHp07-I-T5B015-QQE 80,7 73,9 71,6 69,5 64,3 49,2 37,9 -