Applications
- Water Distribution / Pressure Boosting
- Rainwater Recovering
- Irrigation, Gardening, Sprinklers
- Wash down unit
- Slightly corrosive liquids
COMPACT CLOSE-COUPLED DESIGN
- Compact close-coupled design, robust and corrosion resistant
- Plug-in type power cable and level control (floater) for easy replacement
- Electric pump fitted with threaded connections to allow for easy installation in narrow spaces or, more simply, in line with the pipeline
- Continuous operating either in vertical or horizontal position
HIGH QUALITY MATERIALS
- Heavy duty over size motor shaft
- Stainless steel water proof capsule to protect the motor
- Double mechanical seal separated by an oil chamber* for maximum motor protection
- *In compliance with FDA - Food, Drug Administration - and the annex to G.U. no. 104 of 20/04/73 for oils in contact with food stuffs
Related Products
General features
Model 3 5 9 3 5 9 Frequency: 50 Hz 60 Hz Nominal flow [m3/h] 3 5 9 3 5 9 Liquid temperature range [°C] -5 / +40 Max. Ŋ hydraulic [%] 42.3 56.2 62 42.3 56.2 62 Range [m3/h] 1.5 - 4.5 2.5 - 7.0 5.0 - 14.0 2.0 - 5.5 3.0 - 9.0 6.0 - 16.0 Max. head [m] 98.5 100 91 97 101 74 Pressione max. [bar] 15 Discharge outlet/Connection: Rp threaded for inlet and outlet Power cable: 2 m, type H07RN F Motor power [kW]: 0.55 - 1.5 0.75 - 2.2 1.1 - 3.0 0.55 - 1.5 0.75 - 2.2 1.1 - 3.0 Motor type: Asynchronous
Protection degree: IP68
Insulation class: FMotor standard voltage: Single-phase
(thermal protection built into the motor up to 1.1 kW)220-240 V ± 5 % 220-230V ± 5 % Three-phase
(thermal protection to be provided into the starter panel by the Installer)220-240 V ± 5 %
380-415 V ± 5 %220-230V ± 5 %
380-400V ± 5%Motor frequency of starts: max. 40 starts/hour (with min. 1 minutes resting time) -
VL Hydraulic Performance Table 50 Hz
Electric pump
modelRATED POWER Q = DELIVERY l/min 0 16.6 25.0 33.3 41.7 50.0 75.0 83.3 100.0 125.0 150.0 183.3 233.3 266.7 m³/h 0 1 1.5 2 2.5 3 4.5 5 6 7.5 9 11 14 16 US gmp 0 4.4 6.6 8.8 11.0 13.2 19.8 22.0 26.4 33.0 39.6 48.4 61.6 70.4 [kW] [HP] H = HEAD METERS COLUMN OF WATER [m] VL 3/3 0.55 0.75 34 30.5 28.5 26 24 14 VL 3/4 0.55 0.75 45 40 37.5 34 31 18 VL 3/5 0.75 1 56 49 46 42 38 22 VL 3/6 0.75 1 66 58.5 54 49 44 25 VL 3/7 0.9 1.2 77 67 62 56 50 28 VL 3/8 1.1 1.5 87 75.5 70 63 56 31 VL 3/9 1.5 2 99 87 80.5 73 65 37 VL 3/10 1.5 2 109 95 88 80 71 40 VL 5/4 0.75 1 46 40.5 39 34.5 33 28 18.5 VL 5/5 0.9 1.2 57 50 48 42 40 34 22 VL 5/6 1.1 1.5 67.5 58.5 56.5 49 46 39 24 VL 5/7 1.5 2 79 69 67 58.5 55 47 30 VL 5/8 1.5 2 90 78 75.5 65 61.5 52 32.5 VL 5/9 2.2 3 103 91 88 77 73.5 63 41.5 VL 5/10 2.2 3 114 100 97 85 80.5 69 45 VL 9/3 1.1 1.5 35 31 30 28 25.5 21 10 VL 9/4 1.5 2 47 41 39.5 37 34 28 13 VL 9/5 2.2 3 59 52.5 51 48 44.5 37 18 VL 9/6 2.2 3 70.5 62 60 56.5 52 42.5 20 VL 9/7 3 4 82.5 73 70 66 61 50 24 VL 9/8 3 4 94 82 79 74 68 55 25.5 VL 9/9 3 4 105 91 87 82 74.5 60 26.5 -
VL Hydraulic Performance Table 60 Hz
Electric pump model RATED POWER Q = DELIVERY l/min 0 25.0 29.2 41.7 50.0 58.3 75.0 91.7 100.0 116.7 133.3 150.0 175.0 208.3 241.7 266.7 300.0 m³/h 0 1.5 1.8 2.5 3 3.5 4.5 5.5 6 7 8 9 10.5 12.5 14.5 16 18 US gmp 0 6.6 7.7 11.0 13.2 15.4 19.8 24.2 26.4 30.8 35.2 39.6 46.2 55.0 63.8 70.4 79.3 [kW] [HP] H = HEAD METERS COLUMN OF WATER [m] VL 3/3 0.75 1 49 44 40.5 37.5 34 27.5 19 VL 3/4 0.9 1.2 64.5 57.5 52.5 48.5 44.5 35 24.5 VL 3/5 1.1 1.5 80 70.5 64 59 54 42 29 VL 3/6 1.5 2 96 85 78 71.5 65.5 52 35.5 VL 3/7 1.5 2 111 98 89 82 75 58.5 39.5 VL 5/2 0.75 1 34 30 29.5 28 26 25 22.5 19 15 VL 5/3 0.9 1.2 50 44 43.0 40.5 37.5 36 32 27 20.5 VL 5/4 1.1 1.5 66 57.5 56 52 48 46 40.5 33.5 25 VL 5/5 1.5 2 82 72 70 65.5 60.5 58 51 42.5 32 VL 5/6 2.2 3 99 88 86 80.5 74.5 71.5 64 53 41 VL 5/7 2.2 3 115 101.5 99 92.5 85.5 82 72.5 60 46 VL 9/2 1.1 1.5 34 30 29 28.5 27.5 26 22 17.5 13 VL 9/3 1.5 2 51 45 43 42 40.5 38 33 25 18.5 VL 9/4 2.2 3 68 60 58.5 57 55 51.5 44.5 35 26 VL 9/5 3 4 84.5 74 71.5 69 67 62.5 53.5 41 30 VL 9/6 3.7 5 101.8 89.4 86.8 84.2 81.3 76.2 65.6 50.9 37.1 -
Manuals