4" 3-Phase High Thrust Motors
4" 3-Phase High Thrust Motors
Franklin Electric 4" encapsulated submersible motors, built in ISO 9001 certified facilities for outstanding performance in 4" or larger water wells.
The 3-phase motor offers maximum life and highest efficiency under various load conditions in combination with a 6500 N thrust bearing. It should ideally be combined to the Franklin Electric SubStart/SubTronic3P control boxes for maximum system performance, protection and warranty.
-
Standard Motor Design Specifications
- Hermetically sealed stator with 316SS shell. Anti track, self healing stator resin prevents motor burn out, mechanically supports the winding and provides fast heat dissipation.
- High efficiency electrical design (low operation cost, cool running winding)
- Removable water bloc lead connector
- No-wear, water lubricated radial and thrust bearings for 100 % maintenance free operation
- Non-contaminating FES 93 filling liquid
- Max. storage temperature -15°C - + 50°C
- Various agency approvals for use in drinking water
Brackish Water version Specifications:
- For use in water that has more salinity than fresh water, but not as much as seawater.
- The novel Franklin Electric Brackish Water Motor proposes a cost-effective solution wherever standard 4" motors are not giving sufficient service life.
Pollution Recovery Motor-version Specifications
- Fluorelastomere (Viton®) rubber parts
- Special Polyuretane (PUR) lead assemblies
- 304 graded stainless steel as standard, 316SS as an option
Technical Specification:
- 3-phase High Thrust Motor range: 2.2 – 9.3 kW
- 4" NEMA flange
- Thrust capacity: 6500 N
- Rotation: reversible
- Degree of protection: IP68
- Insulation: Cl.B
- Rated ambient temperature: 30 °C
- Required cooling flow: min. 0.08 m/s
- Max. starts/hr.: 20, equally distributed
- Mounting: vertical to horizontal, shaft upwards
- Voltage tolerance 50 Hz from nominal: -10 % / +6 %
- Voltage tolerance 60 Hz from nominal: ±10 %
- Protection requirements: EN 61947-4-1
Options:
- Motors in full 316SS with SiC seal
- Motors with factory- installed lead in single packing
- Built-in lightning arrestor
- Various cable lengths
- Special voltages on request
- Alternative material executions
Related Products
-
4" 3-Phase High Thrust Motors 50 Hz Model Numbers
PN UN
[V]Digits
1-6Digits 7-10 DOL YΔ
(only 316SS)Standard 304
(40 motor pack)Standard 304
(single pack,
with lead)*316 SS
(40 motor pack)316 SS
(single pack,
with lead)*Pollution
Recovery Motor
(single pack,
with lead)*Brackish
Water Motor
(single pack,
with lead)*2.2 220-230 234 756 234 780 3421 3421L 3521 3521L 3422L 3424L 380-415 234 726 234 770 3421 3421L 3521 3521L 3422L 3424L 500 234 796 - 3421 3421L 3521 3521L 3422L 3424L 3 220-230 234 766 234 781 3421 3421L 3521 3521L 3422L 3424L 380-415 234 764 234 771 3421 3421L 3521 3521L 3422L 3424L 500 234 768 - 3421 3421L 3521 3521L 3422L 3424L 3.7 220-230 234 757 234 782 3421 3421L 3521 3521L 3422L 3424L 380-415 234 727 234 772 3421 3421L 3521 3521L 3422L 3424L 500 234 797 - 3421 3421L 3521 3521L 3422L 3424L 4 220-230 234 767 234 783 3421 3421L 3521 3521L 3422L 3424L 380-415 234 765 234 773 3421 3421L 3521 3521L 3422L 3424L 500 234 769 - 3421 3421L 3521 3521L 3422L 3424L 5.5 220-230 234 758 234 784 3421 3421L 3521 3521L 3422L 3424L 380-415 234 728 234 778 3421 3421L 3521 3521L 3422L 3424L 500 234 798 - 3421 3421L 3521 3521L 3422L 3424L 7.5 220-230 - - 3421 3421L 3521 3521L 3422L 3424L 380-415 234 729 234 780 3421 3421L 3521 3521L 3422L 3424L 500 234 799 - 3421 3421L 3521 3521L 3422L 3424L 9.3 380-415 234 788 - - - - - - - * Lead lengths motors "L": with 2.5 m pre-mounted cable
4" 3-Phase High Thrust Motors - 220/230 V; 380/415 V; 500 V - 50 Hz Performance Data
PN
[kW]Thrust
F[N]UN
[V]nN
[min-1]IN
[A]IA
[A]η(Eff.) [%]
At % loadcos φ [Pf.]
At % loadTN
[Nm]TA
[Nm]50 75 100 50 75 100 2.2 6500 220 2820 9.3 49 71 75 75 0.6 0.74 0.82 7.42 19.87 230 2845 9.5 51.6 69 74 75 0.52 0.66 0.77 7.37 22 380 2820 5.4 28.3 71 75 75 0.6 0.74 0.82 7.42 19.87 400 2845 5.5 29.8 69 74 75 0.52 0.66 0.77 7.37 22 415 2855 5.8 30.9 65 72 74 0.47 0.61 0.72 7.33 23.67 500 2820 4.1 21.5 71 75 75 0.6 0.74 0.82 7.42 19.87 3 6500 220 2820 12.8 69.1 73 77 77 0.61 0.74 0.82 10.16 28.8 230 2845 13 72.8 70 76 76 0.53 0.67 0.77 10.06 31.93 380 2820 7.4 39.9 73 77 77 0.61 0.74 0.82 10.16 28.8 400 2845 7.5 42 70 76 76 0.53 0.67 0.77 10.06 31.93 415 2855 7.9 43.6 67 73 75 0.47 0.61 0.72 10.04 34.33 500 2820 5.6 30.3 73 77 77 0.61 0.74 0.82 10.16 28.8 3.7 6500 220 2815 15.3 86.1 75 79 78 0.62 0.75 0.83 12.6 37.5 230 2840 15.5 90.6 73 77 78 0.54 0.69 0.78 12.5 41.5 380 2815 8.8 49.7 75 79 78 0.62 0.75 0.83 12.6 37.5 400 2840 9 52.3 73 77 78 0.54 0.69 0.78 12.5 41.5 415 2850 9.3 54.3 70 76 77 0.49 0.63 0.73 12.4 44.7 500 2815 6.7 37.8 75 79 78 0.62 0.75 0.83 12.6 37.5 4 6500 220 2820 16.7 93.7 75 78 78 0.6 0.74 0.82 13.5 39.7 230 2840 17.2 98.7 72 77 78 0.52 0.67 0.77 13.4 44 380 2820 9.7 54.1 75 78 78 0.6 0.74 0.82 13.5 39.7 400 2840 9.9 57 72 77 78 0.52 0.67 0.77 13.4 44 415 2855 10.4 59.1 69 75 77 0.47 0.61 0.72 13.4 47.4 500 2820 7.3 41.1 75 78 78 0.6 0.74 0.82 13.5 39.7 5.5 6500 220 2845 21.9 127 77 80 79 0.66 0.79 0.85 18.5 51 230 2865 21.8 133.7 75 79 79 0.59 0.73 0.81 18.3 56.5 380 2845 12.6 73.3 77 80 79 0.66 0.79 0.85 18.5 51 400 2865 12.6 77.2 75 79 79 0.59 0.73 0.81 18.3 56.5 415 2875 12.8 80.1 73 77 79 0.54 0.68 0.77 18.2 60.9 500 2845 9.6 55.7 77 80 79 0.66 0.79 0.85 18.5 51 7.5 6500 380 2830 17.2 94.3 78 80 79 0.66 0.79 0.86 25.3 65.9 400 2855 17.1 99.3 75 79 79 0.58 0,72 0,81 25,1 73.1 415 2865 17.6 103 73 78 79 0.52 0,67 0,77 25 78.6 500 2830 13.1 71.7 78 80 79 0.66 0,79 0,86 25,3 65.9 9.3 6500 380 2830 21.2 108 77 79 79 0.65 0.78 0.86 31.4 73.8 400 2855 21.4 113 75 78 79 0.56 0.71 0.81 31.1 81.8 415 2865 25.4 118 72 77 78 0.46 0.58 0.66 31 88 4" 3-Phase High Thrust Motors - 220/230 V; 380/415 V; 500 V - 50 Hz Winding Resistances
PN
[kW]UN
[V]Stator Ref. U - V / Ohm [Ω] 2.2 220 - 230 326 780 902 2.5 - 3.0 380 - 400 - 415 326 715 902 7.1 - 8.6 500 326 792 902 11.9 - 14.5 3 220 - 230 326 781 902 1.5 - 1.9 380 - 400 - 415 326 716 902 4.7 - 5.8 500 326 793 902 8.4 - 10.2 3.7 220 - 230 326 784 902 1.2 - 1.5 380 - 400 - 415 326 717 902 3.7 - 4.5 500 326 796 902 6.5 - 7.9 4 220 - 230 326 785 902 1.1 - 1.3 380 - 400 - 415 326 718 902 3.3 - 4.0 500 326 797 902 5.8 - 7.1 5.5 220 - 230 326 786 902 0.9 - 1.1 380 - 400 - 415 326 719 902 2.6 - 3.2 500 326 798 902 4.6 - 5.7 7.5 380 - 400 - 415 326 720 902 1.9 - 2.3 500 326 799 902 3.3 - 4.1 9.3 380 - 400 - 415 326 995 920 1.5 - 1.7 4" 3-Phase High Thrust Motors - Lengths & Weights
PN
[kW]304
L [mm]316SS
L [mm]304
[kg]316SS
[kg]Motor with Lead - in Single Pack [mm] [kg] 2.2 422.2 431.4 15 15.5 796 x 100 x 110 16.8 3 477.2 486.4 17 17.5 796 x 100 x 110 18.9 3.7 520.2 529.4 19.1 19.6 796 x 100 x 110 20.9 4 543.2 552.4 20 20.5 796 x 100 x 110 21.8 5.5 652.5 661.7 26.6 27.1 904 x 100 x 110 28.7 7.5 730.5 739.7 30.6 31.1 904 x 100 x 110 32.7 -
3-Phase High Thrust Motor Flat Leads* (VDE / ACS / KTW approved)
2.2 - 7.5 kW Motors Part Numbers L [m] Ø[mm²] Standard 304 SS 316 SS 1.5 3X1.5 1G1.5 310 113 001 310 113 401 310 113 501 2.5 310 113 002 310 113 402 310 113 502 5 310 113 005 310 113 405 310 113 505 10 310 113 010 310 113 410 310 113 510 15 310 113 015 310 113 415 310 113 515 20 310 113 020 310 113 420 310 113 520 30 310 113 030 310 113 430 310 113 530 40 310 113 040 310 113 440 310 113 540 50 310 113 050 310 113 450 310 113 550 9.3 kW Motors Part Numbers L [m] Ø[mm²] 304 SS 2.5 3X1.5 1G1.5 310 116 502K 5 310 116 505K 10 310 116 510K 20 310 116 520K 30 310 116 530K - *Cables are designed for submerged operation. For air operation, please consult Franklin Electric.
3-Phase High Thrust Motor- Pollution Recovery Round Leads 2.2 - 7.5 kW
L
[m]Ø
[mm2]High Thrust Motor- Pollution Recovery Round Leads 2.2 - 7.5 kW 304 SS 316 SS 1.5 4X1.5 310 318 401 310 318 501 2.5 310 318 402 310 318 502 5 310 318 405 310 318 505 10 310 318 410 310 318 510 15 310 318 415 310 318 515 20 310 318 420 310 318 520 30 310 318 430 310 318 530 40 310 318 440 310 318 540 50 310 318 450 310 318 550 - *Cables are designed for submerged operation. For air operation, please consult Franklin Electric.
-