10" REW PM High Efficiency System

10" REW PM High Efficiency System

10" High Efficiency System up to 250 kW

The complete package consisting of variable frequency drive, 10" permanent magnet synchronous motor and output filter offers a compact system solution to meet your water pumping requirements. Well-chosen and perfectly matching components guarantee first-class efficiency and energy saving of up to 7%. The 10" High Efficiency System can be used in either grid or solar applications which makes it a unique and flexible all-in-one solution.

Product Info
Ordering / Performance
Downloads
  • Features & Benefits

    • SUPERIOR EFFICIENCY
    • Up to 7 % improved motor efficiency*
    • Excellent partial load behavior (SKU reduction)
    • One-stop shop and perfectly matching components guarantee first-class performance/efficiency
    • INCREASED LIFETIME
    • Incorporated Soft start and protection features (no additional investment)
    • Speed control (Optimum aggregate operation - pump matches system any time)
    • EASY INSTALLATION & FULLY SUPPORTED
    • Easy system commissioning due to integrated start-up wizard with tailored pre settings.
    • Fully supported by the Technical Support Professionals and Field Service Engineers
    • PACKAGED DEAL
    • 10" rewindable synchronous submersible motor in WW
    • Variable frequency drive
    • Matching output filter
    • Flow switch (Solar systems)
    • Matching submersible pumps available (separately)
    • SOLAR SYSTEM
    • Best-class performance / efficiency, less pv-panels, more water respectively
    • Solar drive available in IP00 enclosure rating
    • AC and DC power source compatible
    • MVPT algorithm maximizes system performance

    Specification:

    • Motor ratings: 200 & 250 kW (100 Hz - 3000 rpm) / 315 & 390 HP (120 Hz – 3600 rpm)
    • System Power Supply: 400 V / 460 V ±10 %
    • Nominal ambient temperature: motor: 30 °C, electronics: 50 °C (> 40 °C with derating)
    • Vertical operation; horizontal operation for 200 kW
    • Protection:
    • motor: IP68, insulation class Y
    • drive: IP00
    • filter: IP00

    Options:

    • Special Voltages
    • IP54 Electronics
    • Further materials: 316SS, 904L
    • Solar version
    • *In comparison to current asynchronous technology
  • Model numbers 400 V (WW synchronous motor, VFD & filter IP00)

    PN
    [kW]
    For panel mount
    VFD IP00 & dV/dt IP00 filterVFD IP00 & Sinus IP00 filter
    190308 028 002308 028 102
    200308 028 001308 028 101
    250308 029 001308 029 101

    Performance data 400 V - 50 Hz

    PN
    [kW]
    Thrust
    F [kN]
    nN
    [min-1]
    IN
    [A]
    IA/IN*
    [A]
    η
    [%]
    cos φTN
    [Nm]
    TA/ TN*
    [Nm]
    308 029 ***250603000497193,80,967961
    220603000423194,30,967011
    200603000377194,50,956371
    308 028 ***200603000389193,80,966371
    185603000354194,10,965891
    150603000284194,30,954781
    • *Since this is an integrated system (motor plus electronics) these figures relate to VFD input
    • **Performance data are based on measurements with Franklin Electric original equipment. For more performance data and product information, please download the pdf version of the product catalog or contact Franklin Electric

    Performance data 460 V - 60 Hz

    PN
    [kW]
    P max.
    [kW]
    Thrust
    F [kN]
    nN
    [min-1]
    IMAX
    [A]
    IA/IMAX*
    [A]
    η
    [%]
    cos φTN
    [Nm]
    TA/ TN*
    [Nm]
    308 029 ***250287603600497193,60,967961
    220253603600423194,30,967011
    200230603600377194,50,956371
    308 028 ***200230603600389193,60,966371
    185213603600354194,10,965891
    150173603600284194,30,954781
    • *Since this is an integrated system (motor plus electronics) these figures relate to VFD input
    • **Performance data are based on measurements with Franklin Electric original equipment. For more performance data and product information, please download the pdf version of the product catalog or contact Franklin Electric.

    Control modes and necessary sensor technologies:

    Process reference Control reference Flow sensor Pressure sensor Level sensorPT100 sensor & Drive slot card
    Q - FlowNo (Optional)mandatoryOptional
    Pmandatorymandatory
    Hmandatorymandatory
    P - pressureNo (Optional)Yes*mandatoryOptional
    Qmandatorymandatory
    Hmandatorymandatory
    H - levelNo (Optional)Yes*mandatoryOptional
    Qmandatorymandatory
    Pmandatorymandatory
    Direct ModeNoYes**NoNoOptional
    Manual ModeNoYes*
    • *Please consult Franklin Electric
    • **Need to be evaluated to PLC