8" High Efficiency Solar System

8" High Efficiency Solar System

Franklin Electric is pleased to announce the introduction of the extended SOLAR feature for its 8" High Efficiency Submersible Borehole systems (HES).
These systems, consisting of a synchronous submersible NEMA motor associated with a variable frequency drive and matching output filter.

Product Info
Ordering / Performance
Downloads
  • System Technical Specifications:

    • One-stop shop – perfectly matching components guarantee first class performance / efficiency
    • Less panels, more water respectively
    • Direct DC feeding
    • Special MPP algorithm for centrifugal borehole pumps
    • Easy set-up due to tailored pre-setting, user interface and Franklin Electric software
    • Reduced amps
    • Smaller drop lead cross size
    • Higher power density
    • Lightweight
    • Significant lower motor heat rise
    • Increased lifetime
    • Communication Modbus (RS485 and Ethernet)

    System Options:

    • Rating: 37 - 150kW
    • Power Supply: Voltage 400 - 800V DC (min. starting voltage 440V)
    • Frequency: 30 - fn (50 respectively 60 Hz)
    • Plug-in card 6x DI/DO - 308 170 201
    • Plug-in card PT100 - 308 170 202
    • Plug-in card Profibus - 308 170 203
    • Plug-in card 1x AI & 2x AO 308 170 206
    • Power supply: 200V & 500V
    • Sinus output filters in IP21
    • Flow switch: 226 019 101
    • Level control switch: 308 170 209
    • DC disconnect:
    • 0 - 11 A/800 V DC - 308 170 313
    • 12 - 22 A/800 V DC - 308 170 325
    • PT100 protection
    • Motors in 316SS and 904L
  • 400V High Efficiency Solar System (Motor, VFD & Filter and Flow switch)

    PN**
    [kW]
    VFD IP21 & Filter IP21
    du/dt FilterSinus Filter
    75308 014 002S*308 014 102S*
    100308 016 002S*308 016 102S*
    150308 017 002S*308 017 102S*



    • *Non-stock items **More ratings and IP54 Kits on demand
    • For lead length > 120 m, please consult Franklin Electric

    Performance Data 400 V-50 Hz / 460 V-60 Hz

    PN
    [kW]
    Thrust
    F [kN]
    nN
    [min-1]
    IN
    [A]
    IA / IN*
    [A]
    η
    [%]
    cos φ
    [%]
    TN
    [Nm]
    TA / TN*
    [Nm]
    308 014 X0275453000128192,50,962391
    308 016 X02100453000178192,70,953191
    308 017 X02150453000270193,40,944771
    • Performance data are based on measurements with Franklin Electric original equipment!
    • *Since this is an integrated system (motor plus electronics) these figures relate to VFD input

    Control Modes and Necessary Technologies:

    Process ReferenceControl
    Refernce
    Flow
    Meter
    Pressure
    Sensor
    Level
    Sensor
    PT100 Sensor &
    Drive Slot Card
    Flow Switch
    (digital)



    SolarNoYes*mandatory
    • *Please consult Franklin Electric