6" High Efficiency System

6" High Efficiency System

In consideration of environmental relief and energy saving Franklin Electric developed a High Efficiency 6" Submersible Borehole System, consisting of a synchronous submersible NEMA motor associated variable frequency drive and output filter.

Product Info
Ordering / Performance
Downloads
  • System Product Advantages:

    • One-stop shop – perfectly matching components guarantee first-class performance
    • Up to 20 % energy saving*
    • System payback < 2 years
    • Up to 13 % improved motor efficiency (system up to 11 %) with excellent partial load behavior*
    • SKU reduction
    • Significant lower motor heat rise
    • Increased lifetime
    • Higher power density*
    • Lightweight
    • Easy set-up due to tailored pre-setting, user interface and Franklin Electric engineered software
    • Speed control
    • Optimum aggregate operation - pump matches system any time
    • Incorporated soft start and protection features
    • Increased lifetime
    • No additonal investment
    • Reduced Amps
    • Smaller drop lead cross size
    • Top class protection with electronics in IP66/54**
    • Easy retrofit - no additional cabinet cost
    • Power factor corrected input
    • No power compensation needed
    • Communication Modbus (RS485 and Ethernet)

    System Technical Specification:

    • Power Supply:
    • Voltage 400 V ± 10 %
    • Frequency 50 Hz ± 6 %

    System Options:

    • Power Supply: 200 V & 500 V
    • PT100 protection
    • Motors in 316SS and 904L
    • Plug-in card 6x DI/DO - 308 170 201
    • Plug-in card - 1x AI & 2x AO 308 170 206
    • Plug-in card PT100 - 308 170 202
    • Plug-in card Profibus - 308 170 203
    • Sinus output filters in IP54 and IP00
    • *In comparison to current asynchronous technology
    • **Alternative electronics in IP21/00 for cabinet assembly available
  • 400 V-50 Hz / 460 V-6 0Hz High Efficiency System (304 SS Motor, VFD & Filter)

    PN
    [kW]
    For Panel mount - VFD IP21 & Filter IPOOFor Wall Mount - VFD IP66 & Filter IP54
    du/dt FilterSinus Filterdu/dt Filter*Sinus Filter
    4308 010 016*308 010 116*308 010 216*308 010 316*
    5.5
    7.5
    9.3308 014 023308 014 123*308 014 223308 014 323*
    11
    13308 014 038308 014 131*308 014 238308 014 338*
    15
    18.5308 014 138*
    22308 016 061308 016 146*308 016 261308 016 361*
    26308 016 161*
    30
    37308 016 087*308 016 187*//
    • *Non-stock items
    • For lead lenght > 120m please consult Franklin Electric

    Control Modes and Necessary Sensor Technologies

    Process ReferenceControl ReferenceFlow MeterPressure SensorLevel SensorPT100 Sensor & Drive Slot CardFlow Switch (digital)
    Q - FlowNo (Optional)mandatoryOptional
    Pmandatorymandatory
    Hmandatorymandatory
    P - pressureNo (Optional)Yes*mandatoryOptional
    Qmandatorymandatory
    Hmandatorymandatory
    H - levelNo (Optional)Yes*mandatoryOptional
    Qmandatorymandatory
    Pmandatorymandatory
    Direct Mode
    NoYes**NoNoOptionalNo
    Manual ModeNoYes*
    SolarNoYes*mandatory
    • *please consult Franklin Electric
    • ** need to be evaluated to PLC

    Performance Data 400 V-50 Hz / 460 V-60 Hz**

    400 V-50 Hz / 460 V-60 HzPN
    [kW]
    Thrust
    F [kN]
    nN
    [min-1]
    IN
    [A]
    IA / IN*
    [A]
    η
    [%]
    PF
    [cos φ]
    TN
    [Nm]
    TA / TN*
    [Nm]
    308 010 X16415.53000 /
    3600
    81880.9512.91
    5.515.53000 /
    3600
    101890.9517.51
    7.515.53000 /
    3600
    13189,50.9523.81
    308 014 X239.315.53000 /
    3600
    18191,50.9529.61
    1115.53000 /
    3600
    201920.95351
    308 014 X381315.53000 /
    3600
    23192.50.9541.51
    1515.53000 /
    3600
    26192.50.9546.11
    18.515.53000 /
    3600
    321920.95591
    308 016 X612227.53000 /
    3600
    391930.95701
    2627.53000 /
    3600
    46192.50.9582.61
    3027.53000 /
    3600
    54191.50.9595.51
    308 016 X873727.53000 /
    3600
    721900.95117.81
    • *Since this is an integrated system (motor plus electronics) these figures relate to VFD input
    • **Performance data are based on measurements with Franklin Electric original equipment! For more Performance Data and Product Information , please down load the pdf Version of the Product Catalog or Contact Franklin Electric Europa.